The complete assembly
Frame tilt changes the physical orientation. Dragging changes only the camera. Playback is slowed 30 times. The arrows trace the toroidal part of the applied field in the fluid.
The disk is 20 cm across. Its outer rim sits inside the ring’s 20.2 cm opening in the nominal calculation. The fluid extends to an outside diameter of 27 cm and surrounds the disk for 360°. At every height, the fluid stays outside the volume swept by the rotor. The small shaft opening belongs to the rotor itself.
A 1 mm radial clearance represents a thin separation between the cold disk at 77 K and the warm fluid at 295 K. Its thickness is a modeling choice. I also tested the ideal limit in which the inner edge of the ring meets the outer edge of the disk. At a 110° tilt the corresponding receiver amplitudes were 27.12 and 27.13 µT on the same grid. This comparison holds the outer radius and liquid inventory fixed and retunes the axial coil to the liquid’s weight.
See the top view and side section at scale
Which effect can be directed?
A field in the ring and at a receiver
In the reference magnetostatic model an ideal continuously wound toroid confines its applied field to the ring. The dry disk starts without trapped flux. I ran that case, then added a circular coupling coil on one face of the same frame. Its flux passes through the spinning superconducting disk. A perfectly closed toroid and a coil threading the bore have different field paths. Toroidal-field derivation
With the coupling coil energized, a point inside the fluid sees a calculated 0.298 mT peak variation at 30 Hz. The disk turns ten times per second at 600 rpm, and its three lobes pass that point three times per turn. Warming the disk above its transition removes this component within the numerical precision of the model.
What the fixed receiver sees
A separate receiver sits 22 cm from the center. Its normal points toward increasing distance from the center and stays fixed in the laboratory. On the spin axis its threefold signal cancels. Among the sampled angles the largest radial signal is 26.8 µT at 110°. An area integral for a hypothetical 100-turn, 1 cm² open-circuit pickup at that angle gives 50.4 µV peak.
The coil settings stay at their upright values during this tilt sweep. The receiver senses a directional near field. Its predicted voltage is an open-circuit readout. Output power under load and the torque required to deliver it would need a coupled circuit and loss model. Faraday induction
Where the force goes
The disk stays centered while it carries a force. In the upright case, the applied and mutually induced fields push the disk 79.84 N down, pull the fluid 57.59 N up and push the windings 22.25 N up. Those are magnetic forces. Adding the disk’s own weight gives an upward holding load of 89.82 N at its fixed center. A magnetic bearing or a mechanical support would have to supply that load.
I also evaluated the magnetic stress on two closed spheres in empty space surrounding the complete assembly. This independently tests for any net force that survives the internal reactions. The result converged to zero. With a separately imposed laboratory field gradient of 0.10 mT/m, the same calculation recovered 0.271 N on the upright device. That case exchanges force with an external magnetic source. Electromagnetic momentum and Maxwell stress
The modeled rotor can place a spin-synchronous signal in the ferrofluid and at an outside receiver. Turning the frame changes what that receiver sees. A propulsion claim would additionally require net momentum transfer. The isolated quasistatic calculation yields zero net thrust.
Force balance, field momentum and gimbal torque
Fwhole = ∮ T·n dA − dPfield/dt · Tmagnetic = (BB − ½B²I)/μ₀
The surface test uses the magnetic quasistatic limit. It integrates the finite current loops and the induced material moments on vacuum spheres of radii 22 and 30 cm. The 45° and 90° retuned cases also have checks on a 31 cm sphere enclosing the side coils. The weak external-gradient check adds a prescribed source-free laboratory field and holds the internal magnetic state at its nominal value to first order. Emitted radiation, any ejected mass, and electromagnetic interactions with nearby material would require additional momentum terms.
The finite-grid disk has a spin angular momentum of 0.329 kg·m²/s at 600 rpm. Tilting its axis at a steady 10°/s calls for about 0.057 N·m of gyroscopic torque. That torque transfers angular momentum to the gimbal while the axis is being turned.
Loads needed to keep the ring fixed
At every tilt the calculation keeps the ring full and the disk center fixed. The upright magnetic support force rotates with the field sources, while gravity keeps pointing straight down in the laboratory. Separately, I adjusted onboard top, bottom and side coils to support the liquid’s integrated weight at several angles.
| Frame tilt | Extra liquid holding load with upright settings (N) | Mismatch after retuning at rotor phase 0 (N) | Largest mismatch at four rotor phases (N) |
|---|---|---|---|
| 0° | 0.00 | 0.0015 | 0.001 |
| 45° | 44.08 | 0.0000 | 0.311 |
| 90° | 81.44 | 0.0000 | 0.167 |
These are loads on components constrained to the same frame. The exact surface of a free liquid also requires local pressure balance around the ring. Testing mirrored points on the specified surface left an upright pressure mismatch of about 0.38 kPa RMS for the 40° upper/lower pair. With the ring sideways and the fields retuned, the opposite sides of the outer equator differed from the static pressure requirement by 12.2 kPa RMS. The field solution carries the net weight at the reference phase. Magnetic retention of this exact, freely suspended liquid shape remains unverified.
How the fixed-surface test works
For a stationary fluid at fixed temperature, the pressure condition contains ∫M d(μ₀H) + μ₀(M·n)²/2 − ρgz and the surface-tension contribution. Here z is height in the laboratory. At equal-curvature pairs on this prescribed ring the capillary terms cancel. Pressures were sampled at 96 azimuths, extrapolating the interior field from two distances. No component is displaced and no fluid shape is evolved. Fixed currents and retuned currents are separate numerical cases. The latter are checked at 0°, 30°, 60° and 90° rotor phase. Magnetic normal traction
Material and numerical assumptions
The rotor is a nominal 1 kg three-lobed YBCO disk at a prescribed 77 K. The fluid is about 5.9 kg of a published type of iron–mercury suspension at a prescribed 295 K. The ferrofluid contains 0.75% iron by mass and the model uses a particle diameter of 4.5 nm. The two temperatures are imposed. The model does not calculate cryogenic heat transfer or assume that liquid mercury can remain liquid at 77 K. Measured YBCO levitation · Measured iron–mercury phase behavior
All reported magnetic signals and forces come from the simulation. The applied fields and actual sample magnetization have not been measured for this apparatus. The calculation uses conventional electromagnetism as a baseline for ESFD. An additional ESFD engine force would require a specified, independently calibrated coupling and a prediction distinguishable from the ordinary electromagnetic and mechanical loads.
Field solver and independent checks
The nonlinear solver updates the induced polarization of both materials with a finite-voxel, isolated-boundary demagnetization kernel. The YBCO uses an isotropic virgin critical-state slab approximation. The fluid uses a reversible Langevin response with its saturation estimated from iron content and bulk iron magnetization. Cut cells keep separate entries for the two material fractions, so their constitutive laws remain distinct near the thin clearance. The reduced material laws omit trapped flux history, eddy-current dynamics in the conducting fluid, drag, pinning hysteresis, and temperature or speed dependence of loss. Bulk iron magnetization
The finite coupling and trim loops are illustrative onboard sources. The upright coil was adjusted to balance the fluid’s net vertical weight. The model prescribes currents and temperatures without calculating the thermal, power or structural demands on real windings. The ideal toroidal source gives 0.040 T applied at the ring centerline. The rotation signal is obtained from quasistatic orientations. The small intrinsic London field expected for steady rotation has a bulk scale of about 0.71 nT at this speed and is outside this material model. London moment in high-temperature superconductors
Horizontal and vertical mesh spacing respectively changed from 6.0/2.8 to 4.3/1.95 to 3.3/1.5 mm. At the reference 110° receiver the nominal 30 Hz peaks over those grids ranged from 26.8 to 27.1 µT. Rebuilding the three-lobed solid at a 37° rotor phase shifted the third harmonic by about 111°, as expected for three lobes. This is a check on the rotational signal. It does not measure the absolute uncertainty of the real apparatus.