Christopher Grenke’s ESFD research · November 24, 2026

Phase alignment in the fixed-ring rotor

When the liquid and piezoelectric drive act together, can the disk cross its spin-mode threshold and deliver a sustained force? This run follows the magnetic field, the spin response, the electrical power and the momentum separately.

What the earlier graph showed

The two curves in the preceding rotor graph came from separate simulations of opposite axial spin alignments. Neither curve represented a second wave simultaneously present in the other run. The previous calculation included a delayed liquid response. It omitted an independently phased piezoelectric drive and the time evolution of the superconducting spin mode.

This calculation keeps the three-lobed, 20 cm YBCO disk at 77 K in the dry center of a complete, fixed 27 cm outer ring of mercury-based ferrofluid at 295 K. The centers remain fixed. The phase study uses the upright frame at 600 rpm. All sensor field traces refer to the same point in the liquid, 11.8 cm from the axis and 3.5 mm above the center plane.

Put both waves on the same clock

Change the electrical command phase. The shortcuts align or oppose either the two axial magnetic signals or the two contributions to the spin-mode stiffness. Positive phase advances a cosine relative to the zero-delay liquid polarization. Time zero is the crest of that reference harmonic.

Disk and liquid fieldPiezo circuit fieldCombined signal
Axial field peakSpin-mode modulationInitial spin growthCycle above |AC| threshold

Open the downloaded HTML in a browser to adjust the phase. The plotted traces and table below show the calculated alignments.

The waveforms show the 30 Hz first harmonic about the mean. An effective axial pickup calibration makes the piezo path equal in amplitude to the original magnetic signal at 30 Hz before spin loading. This is an adjustable example. A fully toroidal field points around the ring. Timing alone cannot turn it into an axial field. The modeled secondary circuit contributes an axial component at the sensor.

Two waveforms add in phase and nearly cancel in opposition. The lower panels show the stability boundary and the nonlinear spin response.
The four panels use one prepared disk spin domain. Spin growth is the rate of a small perturbation to a periodically driven state. The lower-right curves come from a separate 32-second nonlinear integration.

What grew, and where it came from

The direct ESFD tensor coupling and reciprocal SFFD spin–entropy fields were re-solved on the three-dimensional rotor grid. At 30 Hz the disk contributes 1.034 µT of axial magnetic signal at the liquid pickup. The liquid contributes 0.00235 µT with a 43.6° phase lag relative to the disk contribution. These are simultaneous peak amplitudes. Their sum has a 1.036 µT peak. The liquid alone has too little amplitude here to cancel most of the disk signal.

In the proposed hybrid, the mechanical strain from a piezoelectric layer changes the stiffness of the superconducting spin mode. Current delivered to a load supplies a second axial field at the pickup. Strain and current have different phases even when they come from the same layer. In the selected circuit their alignment commands differ by about 5°. Substantially different material or circuit coefficients could shift both commands.

Condition at 30 HzCommandAxial AC peak (µT)Stiffness modulationSpin growth (s⁻¹)
Spin drives aligned+65.49°2.0693.449%+1.153
Spin drives opposed-114.50°0.0910.551%-0.212
Axial fields aligned+70.56°2.0713.445%+1.151
Axial fields opposed-109.45°0.0000.571%-0.202
Zero command phase+0.00°1.6912.916%+0.902

Driving at 65.5° made the liquid and strain contributions to spin stiffness coincide. The 15 Hz disturbance initially grew at 1.153 s⁻¹. In the opposite alignment it decayed at 0.212 s⁻¹. The nonlinear run produced a finite 15 Hz amplitude of 0.143 times the reference ordered spin amplitude over the last six seconds. Flipping the tiny starting disturbance shifted its final 15 Hz response by 180° with the same 30 Hz drive. The phase reference for a 15 Hz force must select which of these two states is occupied.

In a 28–32 Hz drive scan with 0.1 Hz spacing and phase adjusted at each setting, the aligned path grew at sampled frequencies from 29.6 through 30.4 Hz. The opposed path decayed throughout that scan. The archived 15 Hz spin-mode frequency, 30 Hz piezo resonance, losses, material coefficients and delay are example values. The calculation does not identify either as the natural frequency of a built rotor.

The two meanings of “hitting the limit”

The earlier three-lobed rotor paper reported +0.4712 s⁻¹ for the growth of a 15 Hz spin disturbance under 4% modulation at 30 Hz and quality factor 100. This run reproduced that number using the archived equation. Its calculated critical modulation is 2.00001%. A second, older downward-pull graph reported up to 2.476 nm/s² from the mass of a 1 kg ring acting on a separate probe. The last ESFD/SFFD rotor run gave a conditional ±4.45 × 10−30 m/s² at its separate probe using the proposed laboratory density coupling. None of those observables was a positive whole-device thrust measurement.

Section 3 of Grenke’s proof also proposes a material- or domain-dependent ratio χ = ℱ/ℱcrit. A driven oscillator can cross its growth threshold with χ still unknown. If the relevant input is the axial oscillating field, the viewer computes the fraction of each cycle spent above a trial critical amplitude. For example, the 70.6° case spends about 48% of a cycle above |1.50 µT| and the field-opposed case spends zero. The adjustable value is a hypothesis about the projected AC component. A limit defined from the full local field would also have to include the static components and the material’s critical scale. The project papers supply no measured strain-to-spin coefficient or critical field for this composite. No discontinuous change of inertia or force is inserted when the slider is crossed.

Where a signed force enters ESFD

In the proof’s direct spin–field term, an axial moment in a spatial field gradient feels a force. Let the disk’s effective moment be ℳ* y(t), and let a separate external source produce a sinusoidal axial gradient with peak G. For the same frequency, the cycle average is

⟨Fz⟩ = ½ ℳ* G |ỹ| cos(φG − φy).

This is a way for alignment to give a positive signed force on the apparatus when an external field participates. With the 15 Hz gradient phase held fixed at zero, the two stable subharmonic phases in the nonlinear run give +0.0696 and −0.0696 in units of ℳ*G. A 15 Hz moment multiplied by a pure 30 Hz gradient averages to zero. The dataset includes the actual 30 Hz moment harmonic as well. The values in newtons require a measured effective moment and an external gradient. A gradient generated by another onboard component also exerts a reaction on its source.

For the isolated apparatus the proof’s field-momentum accounting also allows recoil when waves carry net axial momentum out of the device. Restoring time dependence to the previous SFFD exterior entropy equation gives k² = (2πf/vs)² − ℓ−2. Using the previous 0.10 m entropy range and the relativistic exterior continuation vs = c puts the propagation threshold at 477 MHz. The linear 15 and 30 Hz exterior entropy harmonics decay in space and carry zero momentum to infinity in this channel.

A second calculation tested what changes if that exterior mode is gapless. Two effective threefold axial sources placed at the modeled disk and fluid centers of volume radiate equal amounts upward and downward when driven exactly in phase in this approximation. A phase offset and an axial separation can give the emitted field a preferred direction. A 90° offset in the illustrative gapless model gives an outgoing axial momentum fraction of about 5.84 × 10−11 at 30 Hz, with the sign reversed at −90°. Its absolute thrust needs the emitted power and source normalization. This sensitivity test substitutes two thin equivalent rings for the full dynamic source. Electromagnetic leakage, other fields and an external laboratory gradient have independent momentum budgets. The available inputs establish neither the total recoil nor a positive propulsion force for the actual device.

Piezoelectric generation and the energy budget

A piezoelectric layer converts changing strain into electrical charge and converts applied voltage into strain. The example keeps YBCO as the superconducting disk and uses an aluminum nitride layer as the transducer. Experiments have coupled aluminum nitride acoustic modes to a superconducting circuit. Those experiments do not give the coefficients, loss or frequency of this rotor. A single proposed replacement material would need both a superconducting transition and a usable electromechanical coupling at its operating temperature. Crystal symmetry, screening, strain transfer and the circuit load then enter the calculation.

There is a material lead if both properties must belong to one chemical compound. Wu et al. measured electrical output from strained odd-layer MoS₂. Costanzo et al. independently observed zero resistance near 2 K in an electrically gated monolayer. The open question is the loaded piezoelectric coefficient while that same film is superconducting. The studies used separate samples and conditions. Neither supplies a bulk substitute for the 77 K rotor. Strain experiment · Superconducting experiment.

With the electrical source switched off and a mechanical input maintained, the example piezo circuit transfers 44.4% of the input work per cycle to its resistive load at 30 Hz. The rest is mechanical loss. With the piezo driven electrically, changing phase is possible because the source supplies or absorbs work. The nonlinear run tracked electrical input, spin-pump work, stored energy and loss. The largest residual was below 3 × 10−10 of integrated input work across the four runs. A passive piezo cannot supply infinite magnetic gain. The 2.07 µT result above depends on choosing a second path of approximately matching amplitude.

Equations and reproduction

Three-dimensional fields and the ordered spin mode

The calculation re-solves the reference fixed-ring ESFD/SFFD system for 43 shaft frequencies. The fields are evaluated within the liquid on the same spatial and azimuthal grid. With j the material-weighted disk and liquid spin current, the field equations are Δψ = ∇·j, bspin = ΛB(j − ∇ψ), and (−Δ + ℓ−2)σ = −η∇·j. Both materials respond to bimposed + bspin + η∇σ. The ring’s polarization has the co-rotating delay factor (1 − Ωτ ∂φ)−1. Magnetization from each material contributes linearly to bspin after the coupled solution. Here SFFD denotes the spin–entropy action which the June equation guide calls SEFD.

Eliminating condensate occupancy n = |Ψ|² from Eq. 55 on its condensed branch gives k = ms² − ua/b and λe = λs − u²/(2b). For k < 0 an ordered minimum has q₀² = −k/λe. The lumped mode uses y = q/q₀ and a time unit 1/ωs. The chosen effective inertia sets ωs = 2π × 15 s⁻¹. The new strain coupling shifts a(T) by gεε, so the spin stiffness can be modulated even though strain preserves the energy’s spin inversion symmetry.

y″ + y′/Qs + ½(y³ − y) + [hr(t) + gxx] y = 0.

Expanding about y = 1 produces both a direct 30 Hz forcing term and a modulation of the small disturbance. A one-period solution and its six-state linearization determine the largest multiplier and growth. A separate integration follows both stable subharmonic phases, loading and finite amplitude for 32 seconds. The frequency scan adjusts the command using the linear piezo transfer at each frequency. The exact phase buttons at 30 Hz use the reciprocally loaded periodic solution.

Circuit, spatial overlap and calibration

In piezo time p = ωpt, x is strain-mode displacement, v the voltage and i the load current. In spin time the piezo derivatives acquire a factor ωp/ωs = 2. The normalized equations are

xpp + xp/Qp + x − θv = Fm − w gx(y² − 1)/2
(v + θx)p = is − i   ·   L ip + Ri = v.

Inputs are Qs = 100, Qp = 16, θ = 0.20, L = 1, R = 0.80 and a spin-to-actuator energy ratio w = 1 in normalized units. The reciprocal term follows from w gxx(y² − 1)/2. The rotor/ring route is prescribed as 2% stiffness modulation before the calculated liquid delay. The piezo route is normalized to 2% at 30 Hz in the unloaded spin limit. Those coefficients and the coil’s axial transfer at the sensor are adjustable. No voltage, current, magnetic geometry or force calibration of a manufactured piezo layer is available.

The model assumes that an azimuthally referenced threefold coupling samples the rotor/ring signal and applies it to the same disk mode as the independently driven strain. An ideal uniform torus averaged over its entire circumference has zero overlap with a pure threefold harmonic. The local 30 Hz signal alone does not establish a drive on a global mode. The piezo stress projects onto one collective coordinate. A full three-dimensional strain tensor, a circuit field map and their feedback on every cell are outside this reduced description. It imposes coherent drive timing and tests the material response. Capture and lock of two autonomous oscillators would require a feedback and noise model.

The retarded exterior calculation

The SFFD vacuum continuation is [vs−2∂t² − ∇² + ℓ−2]σ = −η∇·j. For a propagating mode the recoil per emitted watt is −(k/ω)ξz, where ξz is the emitted-power-weighted mean cosine relative to the upward direction. In the gapless check the source angular amplitude for each thin ring is proportional to μ J₃(kr√(1−μ²)) exp(ikzμ), μ = cos θ. The two effective integrated axial-current amplitudes are equal by assumption. The volume-weighted disk and fluid radii are 6.81 and 11.86 cm. Their axial centroids differ by 0.93 mm. The optional gapless model changes the exterior dispersion, and illustrates how phase can enter a signed momentum integral if a wave propagates. No measured entropy-wave speed or attenuation in this material is available.

Sources